UNIGATE® FALCON Protocol Converter / Gateways for DINrail

  • Norm compliant
  • Certified
  • Configurable
  • Programmable
  • Ready-to-use
  • Designed and manufactured in Germany

Fast / Compact / Flexible UNIGATE FALCON protocol converter/gateway series

The new UNIGATE FALCON series connects devices such as automation components to the desired Industrial Ethernet standard or fieldbus via their serial interface. The RS232/RS485/RS422 interfaces are integrated as standard.
Communication between the serial connection and/or Industrial Ethernet/fieldbus takes place either by configuring the device or with a script.
Standard protocols such as Modbus ASCII, Modbus RTU (master or slave), 3964 (R)  and others can be configured accordingly via the web interface of the UNIGATE FALCON.

Scripts can be created with the free PC software tool 'Protocol Developer'. A script offers the greatest possible flexibility for complex tasks and also enables the implementation of proprietary protocols, for example. Own scripts can be developed on the basis of the available template scripts. Deutschmann Automation also offers the creation of scripts as a service.
The new UNIGATE FALCON series is available as a DIN rail module to IP20 or as an embedded version for direct integration into existing end products. The very slim and compact device can even be installed in a sub-distribution board. All modules for the different bus variants have an identical mechanical design and can therefore be used flexibly or replaced without additional effort. This makes it possible to supply the end devices with any desired bus for optimum integration into the environment.

Another feature is the integrated service functions, which can be called up via a button on the front of the device. A hardware reset or a factory reset, for example, can be carried out without additional equipment.
Another special feature, which is already known from the UNIGATE CL protocol converter, is the brand labeling. Deutschmann offers you not only the option of configuring the device according to customer requirements and choosing different housing colors, but also the option of attaching your logo.

 

Deutschmann Script language - Ultimate Flexibility

For more complex applications, which cannot be represented via a pure configuration, we offer the Deutschmann Script language for the flexible, proprietary protocol connection between the UNIGATE module and the terminal device. With the help of the free Deutschmann software Protocol Developer, you control the data traffic between the application and the bus system without having to change the firmware of the terminal.

Find out more about Protocol Developer

UNIGATE FALCON - Overview

  • Available for most  Industrial Ethernet and fieldbus versions
  • RS232, RS485- and RS422 interfaces are on Board
  • When using the RS485 interface, multiple terminal devices can be used on a Protocol Converter
  • Same design on the serial side in all bus versions
  • The fieldbus or Ethernet side meets the standards, respectively, the standard market models.
  • Brand labeling
  • Adaptation of the terminal device firmware is not required
  • Modern, slim DINrail
  • Uniform dimensions across the entire (product) family
  • Wide voltage rane from 10 to 33 VDC
  • Built-in isolation between all interfaces
  • Configuration via web interface
  • Modbus RTU (Master/Slave)
  • Modbus ASCII (Master/Slave)
  • 3964(R) protocol
  • ASCII protocol
  • SSI protocol for transducer (gray code or binary code)
  • Pre-configured according to customer
  • Free programming with Protocol Developer (Deutschmann Script language)
  • Replica of proprietary protocols
  • USB interface with debug function for script development on board
  • PROFINET interface:

    • PROFINET Conformance Class B (Real-Time, use in an IRT network possible)
    • Max. 1024 bytes of input data and 1024 bytes of output data
    • Cyclical data exchange
    • Acyclical data exchange
    • 100 Mbit/s
    • FTP server
    • Web server
    • PROFINET configuration via GSDML file
    • MRP
    • S2 system redundancy
    • Isolated 2x RJ45 connection (integrated 2 port switch)
  • Serial interfaces:

    • RS232/RS422/RS485 on board
    • Transmission rate max. 6 MBaud

    Implemented protocols:

    • Modbus RTU Master
    • Modbus RTU Slave
    • Modbus ASCII Master
    • Modbus ASCII Slave
    • SSI (on request)
    • 3964R
    • ASCII
  • Ethernet interface:

    • TCP/P configuration via web interface
    • Isolated 1x RJ45 connection
    • 1TCP/IP socket interface

     

  • 1CAN-FD interface:

    • CANopen
    • CAN Layer 2 (CAN-FD/CAN 2.0A/CAN 2.0B)

Technical data

Variant DIN rail
Diemensions    (WxDxH in mm) 25 x 95 x 95 (connector plug included)
Weight approx. 105 g
Protection class IP20
Housing material Polyamid
Mounting DINrail (EN 50022)
Power supply 10 up to 33 Volt DC Protection against incorrect polarity, short circuit and overload integrated
Operating temperature -25°C (non condensing) up to +70°C
Storage-/transport temperature -40°C ... +100°C
Interfaces:  
Serial RS232/RS422/RS484 up to 6 MBaud
PROFINET

PROFINET device interface, conformance class B, real-time communication (RT)

Note: Can also be operated in an IRT network.

1Ethernet 100Base-TX
1CAN CANopen, CAN-FD, CAN 2.0A, CAN 2.0B
Galvanic division CAN-FD
1Option Activation via chargeable activation code

Order data

Order designation Description Order number
UNIGATE FN-PRO-PN Mounting: On DIN rail; Operating voltage: 10-33V/DC; Connection type plug: Push-in spring connection; Front cover: transparent hinged cover; Service menu (via push-button); Available interfaces: PROFINET device interface (2 port switch), serial interfaces (RS232, RS422 and RS485), Ethernet interface (configuration), debug interface (via µ-USB); Configuration via web interface or individual script (Software Protocol Developer); Optional: CAN interface (CANopen/CAN Layer 2/CAN FD), Fast Ethernet 1Port interface, USB-A, back panel bus (FXport); device color: Front blue, housing + connector black (blue: similar to RAL 5015) (black: similar to RAL 9005) V6000
UNIGATE FN-PRO-GY-PN Mounting: On DIN rail; Operating voltage: 10-33V/DC; Connection type plug: Push-in spring connection; Front cover: transparent hinged cover; Service menu (via push-button); Available interfaces: PROFINET device interface (2 port switch), serial interfaces (RS232, RS422 and RS485), Ethernet interface (configuration), debug interface (via µ-USB); Configuration via web interface or individual script (Software Protocol Developer); Optional: CAN interface (CANopen/CAN Layer 2/CAN FD), Fast Ethernet 1Port interface, USB-A, back panel bus (FXport); device color: Front + housing + connector light grey (light grey: similar to RAL 7035) V6001
Optional Customized design on request