UNIGATE® FALCON Embedded  Ready for immediate integration

  • Norm compliant
  • Certified
  • Programmable
  • Designed & manufactured in Germany

Embedded version of the UNIGATE FALCON protocol converter/gateway series that can be integrated immediately

The EMBEDDED version of the new UNIGATE FALCON series includes the same functions that are also supported by the DIN rail module version. These include the RS232/RS422/RS485 serial interfaces available as standard, as well as the respective Industrial Ethernet or fieldbus interface.

Thanks to the low installation height of approx. 25 mm, the embedded version is also suitable for installation situations where space is limited and a redesign of the existing electronics is not planned. All modules for the different bus variants have an identical mechanical design and can therefore be used flexibly. They are mounted using 4 holes, each with a diameter of 3 mm. This makes it possible to retrofit end devices with the required Industrial Ethernet or fieldbus.

Communication between the serial connection and/or Industrial Ethernet/fieldbus is carried out either by configuring the device or with a script.

Standard protocols such as Modbus ASCII, Modbus RTU (master or slave), 3964 (R) and others can be configured accordingly via the web interface of the UNIGATE FALCON.

Scripts can be created with the free PC software tool 'Protocol Developer'. A script offers the greatest possible flexibility for complex tasks and also enables the implementation of proprietary protocols, for example. Own scripts can be developed on the basis of the available template scripts. Deutschmann Automation also offers the creation of a script as a service.

Deutschmann Script language - Ultimate Flexibility

For more complex applications, which cannot be represented via a pure configuration, we offer the Deutschmann Script language for the flexible, proprietary protocol connection between the UNIGATE module and the terminal device. With the help of the free Deutschmann software Protocol Developer, you control the data traffic between the application and the bus system without having to change the firmware of the terminal.

Find out more about Protocol Developer

UNIGATE FALCON EMBEDDED - Overview

  • Available for most  Industrial Ethernet and fieldbus versions
  • RS232/RS485/RS422 on Board
  • When using the RS485 interface, multiple terminal devices can be used on a Protocol Converter
  • Same design on the serial side in all bus versions
  • The fieldbus or Ethernet side meets the standards, respectively, the standard market models
  • Adaptation of the terminal device firmware is not required
  • Mounting via 4 mounting holes Ø 3,0mm
  • Wide voltage rane from 10 to 33 VDC
  • Built-in isolation between all interfaces
  • Configuration via web interface
  • Modbus RTU (Master/Slave)
  • Modbus ASCII (Master/Slave)
  • 3964(R) protocol
  • ASCII protocol
  • SSI protocol for transducer (gray code or binary code)
  • Pre-configured according to customer
  • Free programming with Protocol Developer (Deutschmann Script language)
  • Replica of proprietary protocols
  • USB interface with debug function for script development on board

PROFINET interface:

  • PROFINET Conformance Class B (Real-Time, use in an IRT network possible)
  • Max. 1024 bytes of input data and 1024 bytes of output data
  • Cyclical data exchange 
  • Acyclical data exchange 
  • 100 Mbit/s
  • FTP server
  • Web server
  • PROFINET configuration via GSDML file
  • MRP
  • S2 system redundancy
  • Isolated 2x RJ45 connection (integrated 2 port switch)

Serial interfaces:

  • RS232/RS422/RS485 on board
  • Transmission rate max. 6 MBaud

Implemented protocols:

  • Modbus RTU Master
  • Modbus RTU Slave
  • Modbus ASCII Master
  • Modbus ASCII Slave
  • SSI (on request)
  • 3964R
  • ASCII

Ethernet interface:

  • TCP/IP configuration via web interface
  • Isolated 1x RJ45 connection
  • 1TCP/IP socket interface

1CAN-FD interface:

  • CANopen
  • CAN Layer 2 (CAN-FD/CAN 2.0A/CAN 2.0B)

Technical data

Variant Embedded
Dimensions EM3  (LxWxH in mm) 84 x 77 x 18 
Weight approx. 47 g
Housing material without housing
Mounting 4 y 3,0mm Ø mounting holes
Power supply 10 up to 33 Volt DC Protection aiaginst incorrect polarity, short circuitand overload integrated
Operating temperature -25°C (non condensing) up to +70°C
Storage-/transport temperature -40°C ... +100°C
Interfaces:  
Serial RS232/RS422/RS485 up to 6 MBaud
PROFINET

PROFINET device interface, conformance class B, real-time communication (RT)

Note: Can also be operated in an IRT network.

1Ethernet 100Base-TX
1CAN CANopen, CAN-FD, CAN 2.0A, CAN 2.0B
Galvanic division CAN-FD
1Options Activation via chargeable activation code

Order data

Order designation Description Order number
UNIGATE FN-PRO-EM3-PN Mounting: Individually via 4 mounting holes ⌀ 3.0mm; Operating voltage: 10-33V/DC; Connection type plug: without connectors; Service menu (via push-button); Available interfaces: PROFINET device interface (2 port switch), serial interfaces (RS232, RS422 and RS485), Ethernet interface (configuration); debug interface (via µ-USB); Configuration via web interface or individual script (Software Protocol Developer); Optional: CAN interface (CANopen/CAN Layer 2/CAN FD), Fast Ethernet 1Port interface, USB-A, back panel bus (FXport). on request
Optional Other versions on request on request