#Profibus_DP ; ; IMPORTANT: ; This is a template. You may use it as a basis for the development of your ; device's GSD file. You may only use Ident numbers that have been assigned ; to you by the certification office (pls. see links below). ; Please note: The Ident number needs to be set in the device's script as well. ; ; Please make use of the information and documentation available from PI on www.profibus.com. ; https://www.profibus.com/products/product-certification/ ; https://www.profibus.com/products/certification-office/ ; https://www.profibus.com/download/ ; GSD_Revision = 5 Ident_Maintenance_supp = 1 ; Vendor_Name = "Deutschmann Automation" Model_Name = "UNIGATE IC2 PROFIBUS" Revision = "V1.7" Ident_Number = 0x3218 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "A" Software_Release = "1.0.x" ; 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 ; MaxTsdr_9.6 = 15 MaxTsdr_19.2 = 15 MaxTsdr_45.45 = 15 MaxTsdr_93.75 = 15 MaxTsdr_187.5 = 15 MaxTsdr_500 = 15 MaxTsdr_1.5M = 20 MaxTsdr_3M = 35 MaxTsdr_6M = 50 MaxTsdr_12M = 95 ; Redundancy = 0 Repeater_Ctrl_Sig = 2 24V_Pins = 0 Implementation_Type = "UNIGATE IC2" Bitmap_Device = "UG-IC2PB" ; Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 1 Publisher_supp = 1 ;data transfer to other slaves possible (DPV2-publisher) ; Modular_Station = 1 Max_Module = 16 Max_Input_Len = 244 Max_Output_Len = 244 Max_Data_Len = 488 Modul_Offset = 0 ; Fail_Safe = 0 Slave_Family = 9 Max_Diag_Data_Len = 11 ; DPV1_Slave = 1 C1_Read_Write_supp = 1 C1_Max_Data_Len = 80 ;excluding function_num, slot_number, index, length C1_Response_Timeout = 300 Max_Initiate_PDU_Length = 52 C2_Read_Write_supp = 1 C2_Max_Data_Len = 80 ;excluding function_num, slot_number, index, length C2_Response_Timeout = 300 C2_Read_Write_required = 1 C2_Max_Count_Channels = 2 ; DPV1_Data_Types = 0 ; Max_User_Prm_Data_Len = 237 ;9..237, depending on actual hardware used. ; PrmText=1 Text(0)="disabled" Text(1)="enabled" EndPrmText ExtUserPrmData=1 "DPV1mode" Bit(7) 0 0-1 Prm_Text_Ref=1 EndExtUserPrmData Ext_User_Prm_Data_Const(0) = 0x00,0x00,0x00 Ext_User_Prm_Data_Ref(0) = 1 ; ; Module = "1 byte I/O (consistent)" 0xB0 1 EndModule Module = "2 byte I/O (consistent)" 0xB1 2 EndModule Module = "4 byte I/O (consistent)" 0xB3 3 EndModule Module = "8 byte I/O (consistent)" 0xB7 4 EndModule Module = "16 byte I/O (consistent)" 0xBF 5 EndModule Module = "16 words I/O (consistent)" 0xFF 6 EndModule Module = "32 words I/O (consistent)" 0xFF,0xFF 7 EndModule ; Module = "64 words I/O (inconsistent)" 0xFF,0xFF,0xFF,0xFF Module = "64 words I/O (consistent)" 0xC0,0xFF,0xFF 8 EndModule Module = "122 words in" 0x5F,0x5F,0x5F,0x5F,0x5F,0x5F,0x5F,0x59 9 EndModule Module = "122 words out" 0x6F,0x6F,0x6F,0x6F,0x6F,0x6F,0x6F,0x69 10 EndModule ; Module = "1 byte in 1 byte out (cons.)" 0x90,0xA0 11 EndModule Module = "8 byte in 8 byte out (cons.)" 0x97,0xA7 12 EndModule Module = "16 byte in 16 byte out (cons.)" 0x9F,0xAF 13 EndModule Module = "16 words in 16 words out (cons.)" 0xDF,0xEF 14 EndModule ;