#Profibus_DP ; ; Historie: ; ========= ; V1.0 01.12.2004 La Original (abgeleitet aus L100) ; V1.1 24.03.2005 La modul "S7DB (universal)" new, other modules disabled; ; GSD_Revision = 2 ; Vendor_Name = "Deutschmann Automation GmbH" Model_Name = "LOCON-200-PB" Revision = "V1.1" Ident_Number = 0x3687 Protocol_Ident = 0 ; PB-DP Station_Type = 0 ; Slave FMS_supp = 0 Hardware_Release = "A" Software_Release = "V2.1" OrderNumber = "V3487" ; 9.6_supp = 1 19.2_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 ; MaxTsdr_9.6 = 15 MaxTsdr_19.2 = 15 MaxTsdr_45.45 = 15 MaxTsdr_93.75 = 15 MaxTsdr_187.5 = 15 MaxTsdr_500 = 15 MaxTsdr_1.5M = 20 MaxTsdr_3M = 35 MaxTsdr_6M = 50 MaxTsdr_12M = 95 ; Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Implementation_Type = "VPC3" Bitmap_Device = "L200" ; Freeze_Mode_supp = 1 Sync_Mode_supp = 1 Auto_Baud_supp = 1 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 1 ; Modular_Station = 1 Max_Module = 17 Max_Input_Len = 39 Max_Output_Len = 31 Max_Data_Len = 70 Modul_Offset = 0 ; Fail_Safe = 0 Slave_Family = 10 ;SPS Max_Diag_Data_Len = 8 ; Max_User_Prm_Data_Len = 3 User_Prm_Data_Len = 3 User_Prm_Data = 0x00,0x00,0x00 ; ; Bei L200 gibt es 2 Ausführungen des Basismoduls: ; ; 1. S7-Mode ; ========== ; Der Datenaustausch mit einer S7 erfolgt über einen mitgelieferten Handlingsbaustein. ; Die Programmierung (Nocken, Totzeiten...) werden NICHT im nichtflüchtigen Speicher abgelegt, ; da der Handlingsbaustein diese Daten nach jedem Einschalten an das L200 schickt. ; ;Module = "L200-Basis(S7-Mode)" 0xB7,0xA1,0x99 ; don't use for new projects ;EndModule ; ; The following modul will be used in all Deutschmann cam-switch units (R80,R100,L100,L200) ; ; Data S7->L200(Basis): Logik Logikinputs (optional) ; +----+-- ... --+----+----+----+.......+ ..... +.......+ ; |Multiplexer for DB |1-8 |9-16| 1.IO8 | | n.IO8 | ; +----+-- °°° --+----+----+----+.......+ ..... +.......+ ; 0 1 ... 6 7 8 9 ; ; Data L200(Basis)->S7: IO's IO's (optional) ; +----+-- ... --+----+----+----+----+----+----+----+----+----+----+----+.......+ ..... +.......+ ; |Multiplexer for DB | Position | Speed |Prog|Err.|1-8 |9-16| 1.IO8 | | n.IO8 | ; +----+-- °°° --+----+----+----+----+----+----+----+----+----+----+----+.......+ ..... +.......+ ; 0 1 ... 6 7 8 9 10 11 12 13 14 15 16 17 ; ; ; 2 byte logik (8..1,16..9) from S7 ----------------------------------------+ ; 2 byte for actual outputs (8..1,16..9) ------------------------------+ | ; 1 byte for actual error code -----------------------------------+ | | ; 1 byte for actual program ---------------------------------+ | | | ; 1 word for speed -------------------------------------+ | | | | ; 2 words for position -----------------------------+ | | | | | ; 8 byte multiplexer for DB-transfer ----------+ | | | | | | ; v v v v v v v Module = "L200-Basis(S7-Mode)" 0xB7,0xD1,0xD0,0x90,0x90,0x91,0xA1 EndModule ; ; 2. Kommprof-Mode ; ================ ; Die Programmierung wird im nichtflüchtigen Speicher des L200 abgelegt. Die Programmierung erfolgt über das ; Deutschmann-Nockenschaltwerks-Profil oder WINLOC. ; Module = "L200-Basis(Kommprof-Mode)" 0xBC,0xA1,0x99 EndModule ; ; Es können bis zu 16 IO8-Module an die Basis angeschaltet werden. ; Für jedes IO8-Modul muss das nachfolgende GSD-Modul einmal beim Projektieren aufgerufen werden. ; Module = "L200-IO8" 0x30 EndModule